What fixture-level water metering is, how it differs from a unit submeter, and why it works in buildings with no separate pipe per unit.
Fixture-level water metering measures water at individual toilets, showers, sinks and appliances, instead of at a building's master meter or a pipe to each apartment. DrizzleX meters water at the fixture level, so owners see not just how much water each unit used but which fixture used it, and whether it was a leak, overuse or a high-flow fixture.
DrizzleX calls this fixture-level water intelligence. A toilet that starts running on Monday shows up on Monday, not on next quarter's water bill.
Meters are often grouped by how they measure, mechanical or electronic, as PNNL's water metering guide explains. For owners, the more useful split is where the meter sits. EPA WaterSense's February 2026 guide, Know Your Flow and Curb Water Waste, separates point-of-entry devices, "usually installed on the main water line," from point-of-use devices, "installed directly at a water fixture."
For how unit submeters work for billing, see what water submetering is.
Because there's no single pipe to put them on. Accurate submetering "requires each unit be supplied with a single pipe source for water," but conventional multifamily buildings "are plumbed by sector, rather than by unit," according to the Department of Energy's Building America Solution Center (last updated 2017). So most stay on one master meter, and owners either include water in the rent or split the bill by formula, using RUBS.
The same DOE guide names the alternative: "flow sensors or end-use meters can be attached to major water-using appliances." That's fixture-level metering, and it needs no separate unit main.
New construction is heading the same way. Colorado's HB26-1013, signed in March 2026, requires residential buildings permitted from July 1, 2027 to be metered by the utility or a submeter.
About 20% of toilets leak, according to EPA WaterSense. A stuck fill valve can waste 4,300 gallons a day.
A unit total says 3A used twice as much water as 3B. It can't say why. A leak needs a repair, overuse needs a conversation with the resident, and a high-flow fixture needs a replacement. Normal use splits roughly into thirds: toilets, showers and everything else. A leak skews that split, which is how it gets spotted.
Floor leak sensors can't do this job; a running toilet sends its water down the drain. That's why most leak detection only catches floods.
No. A point-of-use device "can only detect leaks at the end use," according to EPA WaterSense. Owners choose which fixtures to meter, often starting with toilets, and the software compares fixture totals with the city water bill, so a gap points to unmetered fixtures or a pipe leak.
The toilet-first approach works. In an EPA case study, a low-income senior housing community put in-line monitors on over 1,000 toilets and, after fixing leaks, cut water use 25%, saving over 1 million gallons.
Cut the waste. In DrizzleX customer buildings, water use has fallen 20–40%, with payback in 2 to 8 months, depending on local rates, plumbing and which fixtures are metered.
Bill on actual use. With a measured total for each unit, owners can bill residents through their own provider, a billing partner or in-house; DrizzleX supplies the data.
At a 5% cap rate, every $1 of annual water expense prevented adds about $20 of building value.
Installation takes about 15 minutes per apartment, with no plumber, and each device carries a 10-year warranty and battery guarantee. For how it compares with other options, see 8 water conservation technologies.
Send us six months of water bills and your tenant count. We'll return a per-building estimate of the waste we'd expect to find.
It measures water at individual fixtures, such as toilets, showers and sinks, rather than at a building's master meter. Software adds the readings into unit totals and flags abnormal flow.
Yes. It measures one fixture instead of one apartment, and adding up an apartment's fixtures gives the same unit total, plus which fixture used the water.
Yes, at the fixture level, with no re-plumbing. Unit submeters need "a single pipe source" for each unit, per the DOE's Building America Solution Center. Fixture-level meters go on each fixture's own supply line instead.
Point-of-entry devices sit on the main water line and see the whole building. Point-of-use devices sit at a fixture and see that fixture in detail, according to EPA WaterSense.
No. Many owners start with toilets alone. Comparing metered totals with the city bill shows any gap.
In DrizzleX customer buildings, water use has fallen 20–40%, with payback in 2 to 8 months, depending on rates, plumbing and which fixtures are metered.
Fixture-level water intelligence