What is fixture-level water metering?

What fixture-level water metering is, how it differs from a unit submeter, and why it works in buildings with no separate pipe per unit.

What is fixture-level water metering?

‍

Fixture-level water metering measures water at individual toilets, showers, sinks and appliances, instead of at a building's master meter or a pipe to each apartment. DrizzleX meters water at the fixture level, so owners see not just how much water each unit used but which fixture used it, and whether it was a leak, overuse or a high-flow fixture.

‍

DrizzleX calls this fixture-level water intelligence. A toilet that starts running on Monday shows up on Monday, not on next quarter's water bill.

‍

How does fixture-level water metering work?

‍

  1. A meter on the fixture. A small device fits the fixture's supply line, from 3/8″ to 2″, and measures flow in gallons.
  2. Readings by LoRa. Data travels over a low-power, long-range radio network. No Wi-Fi needed.
  3. Unit totals, built from fixtures. The software adds up each apartment's fixtures, so you get a unit total without a unit meter.
  4. A baseline for each fixture. It learns what normal looks like for each fixture and flags flow that breaks the pattern, minute by minute.
  5. Alerts ranked by cost. Your team fixes the most expensive waste first.

‍

What are the different types of water meters?

‍

Meters are often grouped by how they measure, mechanical or electronic, as PNNL's water metering guide explains. For owners, the more useful split is where the meter sits. EPA WaterSense's February 2026 guide, Know Your Flow and Curb Water Waste, separates point-of-entry devices, "usually installed on the main water line," from point-of-use devices, "installed directly at a water fixture."

‍

Three levels of water metering in an apartment building
Feature Master meter Unit submeter Fixture-level meter
What it measures The whole building One apartment One fixture
Needs a separate pipe to each unit No Yes No
Shows which unit No Yes Yes, by adding up its fixtures
Shows which fixture No No Yes
Tells a leak from overuse No No Yes
Supports billing on actual use No Yes Yes
Best for Paying the utility Buildings with one line per unit Any building, including shared risers

Point-of-entry and point-of-use terms: EPA WaterSense, “Know Your Flow and Curb Water Waste” (Feb 2026)

‍

For how unit submeters work for billing, see what water submetering is.

‍

Why can't most apartment buildings use unit submeters?

‍

Because there's no single pipe to put them on. Accurate submetering "requires each unit be supplied with a single pipe source for water," but conventional multifamily buildings "are plumbed by sector, rather than by unit," according to the Department of Energy's Building America Solution Center (last updated 2017). So most stay on one master meter, and owners either include water in the rent or split the bill by formula, using RUBS.

‍

The same DOE guide names the alternative: "flow sensors or end-use meters can be attached to major water-using appliances." That's fixture-level metering, and it needs no separate unit main.

‍

New construction is heading the same way. Colorado's HB26-1013, signed in March 2026, requires residential buildings permitted from July 1, 2027 to be metered by the utility or a submeter.

‍

What does fixture-level data tell you that a total can't?

‍

About 20% of toilets leak, according to EPA WaterSense. A stuck fill valve can waste 4,300 gallons a day.

‍

A unit total says 3A used twice as much water as 3B. It can't say why. A leak needs a repair, overuse needs a conversation with the resident, and a high-flow fixture needs a replacement. Normal use splits roughly into thirds: toilets, showers and everything else. A leak skews that split, which is how it gets spotted.

‍

Floor leak sensors can't do this job; a running toilet sends its water down the drain. That's why most leak detection only catches floods.

‍

Does fixture-level metering see everything?

‍

No. A point-of-use device "can only detect leaks at the end use," according to EPA WaterSense. Owners choose which fixtures to meter, often starting with toilets, and the software compares fixture totals with the city water bill, so a gap points to unmetered fixtures or a pipe leak.

‍

The toilet-first approach works. In an EPA case study, a low-income senior housing community put in-line monitors on over 1,000 toilets and, after fixing leaks, cut water use 25%, saving over 1 million gallons.

‍

What can owners do with fixture-level data?

‍

Cut the waste. In DrizzleX customer buildings, water use has fallen 20–40%, with payback in 2 to 8 months, depending on local rates, plumbing and which fixtures are metered.

‍

Bill on actual use. With a measured total for each unit, owners can bill residents through their own provider, a billing partner or in-house; DrizzleX supplies the data.

‍

At a 5% cap rate, every $1 of annual water expense prevented adds about $20 of building value.

‍

Installation takes about 15 minutes per apartment, with no plumber, and each device carries a 10-year warranty and battery guarantee. For how it compares with other options, see 8 water conservation technologies.

‍

See what's running in your buildings

‍

Send us six months of water bills and your tenant count. We'll return a per-building estimate of the waste we'd expect to find.

‍

Get Your Estimate

‍

FAQ

‍

What is fixture-level water metering?

‍

It measures water at individual fixtures, such as toilets, showers and sinks, rather than at a building's master meter. Software adds the readings into unit totals and flags abnormal flow.

‍

Is a fixture-level meter a submeter?

‍

Yes. It measures one fixture instead of one apartment, and adding up an apartment's fixtures gives the same unit total, plus which fixture used the water.

‍

Can you submeter an apartment without separate water lines?

‍

Yes, at the fixture level, with no re-plumbing. Unit submeters need "a single pipe source" for each unit, per the DOE's Building America Solution Center. Fixture-level meters go on each fixture's own supply line instead.

‍

What's the difference between point-of-use and point-of-entry water monitoring?

‍

Point-of-entry devices sit on the main water line and see the whole building. Point-of-use devices sit at a fixture and see that fixture in detail, according to EPA WaterSense.

‍

Do you need a meter on all fixtures?

‍

No. Many owners start with toilets alone. Comparing metered totals with the city bill shows any gap.

‍

How much can fixture-level metering save?

‍

In DrizzleX customer buildings, water use has fallen 20–40%, with payback in 2 to 8 months, depending on rates, plumbing and which fixtures are metered.

‍

Fixture-level water intelligence

See every drop.
Keep every dollar.